  Datasheet File OCR Text:
 Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
KYL-812 wireless ON-OFF input and output module user manual
Shenzhen KYL Communication Equipment Co., Ltd
Address: Unit 5-7, Building3, Huangdu Square, South of Exhibition Center, Yitian Road, Futian District, Shenzhen Guangdong China Tel: +86-0755-83410815 Fax: +86-0755-83408785 Skype Skypelxmlosia Yahoo messenger: losia2012@yahoo.com MSN: kylcom01.com@hotmail.com E_mail: sales01@rf-data.com/kyl03losia@gmail.com Website: http://www.rf-data.com
Fax: +86-0755-83408785
kyl03losia@gmail.com
www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. KYL-812 wireless ON-OFF input and output module is a wireless transmission equipment with four 4-channel DI and 4-channel relay DO. I. Function 4 channel ON-OFF DI and DO transmitting timely. The 4 channel ON-OFF condition for the transmitting equipment can be output timely at the receiver equipment. That is the ON-OFF condition for the transmitting equipment is shut down, while the ON-OFF condition will be shut down at the receiver equipment; and the transmitting equipment is disconnect, while the receiver equipment will disconnect. The following is the schematic diagram of the ON-OFF transmission.
Schematic diagram II Feature: IIFeature: 1 2 3 4 4-channel coupler isolated inputs, high reliability and stability. 4-channel relay dry contact output, contact current is 30V 1A. 4-channel 5V voltage output collocate wireless data transmission module with 2-3km.
kyl03losia@gmail.com
www.rf-data.com
Fax: +86-0755-83408785
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. Working frequency 433MHz(400-470MHz); RF power: 500mW; Receive sensitivity: -120dBm 5 6 7 Receive current: 30mA; transmitting current: 300mA Power supply: DC 9-15V Size: 82mm*82mm
III. DIP switch definition III. DIP8Working mode choosing: ON--send the inputting conditions. The module will send the inputting conditions of the 4-channel ON-OFF OFF--send timely every 1s or 2s; principal equipment will send the 4-channel input condition to the subordinate equipment (non-realtime transmission) DIP7Principal and subordinate mode choosing under the timing mode: ON--subordinate equipment, OFF--principal equipment DIP6Sending interval choosing under the timing mode: ON--slow(2s one time), OFF--fast(1s one time) DIP5No definition DIP1-4Channels choosing (max 16 channels) The following is the channel correspondence table for DIP switch 1-16:
DIP NO.
Channel No.
DIP NO.
Channel No.
DIP NO.
Channel No.
DIP NO.
Channel No.
Fax: +86-0755-83408785
kyl03losia@gmail.com
www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
1 5 9 13
2
6
10
14
3
7
11
15
4
8
12
16
Note: * Users generally use the inputting change sending mode, DIP7-ON; * To avoid more than two remote control systems working at the same time in one remote control range, the module for different system should choose different channel (working frequency); * Under the timing mode, it should be one subordinate equipment, and one principal equipment; * It should be effect by re-power on the module after changing the DIP position. VI. Connection Definition
Connection name Pin No. COM1 1 2 1 2 3 4 5 6 Definition GND VCC IN1 GND IN2 GND IN3 GND
kyl03losia@gmail.com
Remarks Grounding of power supply DC9-15V First group ON-OFF input Second group ON-OFF input Third group ON-OFF input
www.rf-data.com
COM2
Fax: +86-0755-83408785
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 IN4 GND GND LED1 GND LED2 GND LED3 GND LED4 OUT1 OUT2 OUT3 OUT4 Fourth group ON-OFF input First channel voltage controlling output (5V) Second channel voltage controlling output (5V) Third channel voltage controlling output (5V) Fourth channel voltage controlling output (5V) First channel relay dry contact output Second channel relay dry contact output Third channel relay dry contact output Fourth channel relay dry contact output
COM3
COM4
V: Using method 1First according to your using requirement, setting the DIP switch and connecting the power(12V), the switch input and the correspondence switch output by following the above instruction. 2Turn on the power 3 is the contact sending mode and the working channel is No.1 default. It
Fax: +86-0755-83408785
kyl03losia@gmail.com
www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd Shenz Co.
IV. Exterior sketch map
Fax: +86-0755-83408785
kyl03losia@gmail.com
www.rf-data.com